Open the Piping Specification.xls workbook.
-
Select the InsideSurfaceTreatment sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Row.
-
In the Spec Name column, type the name of your piping materials class.
-
In the Nominal Piping Diameter From column, type the nominal pipe diameter (NPD) that specifies the start of the treatment range.
-
In the Nominal Piping Diameter To column, type the NPD that specifies the end of the treatment range.
-
In the Nominal Piping Diameter Units column, type the units for the NPDs. For example, type mm or in.
-
In the Inside Surface Treatment column, type the interior surface treatment code that you want to use for the defined NPD range.
-
Save the Piping Specification.xls workbook.
-
The piping materials class must be defined on the PipingMaterialsClassData sheet.
-
The valid interior surface treatment codes are listed in the AllCodeLists.xls workbook on the InteriorSurfaceTreatment sheet in the Codelist Number column.