Open the Piping Specification.xls workbook.
-
Select the BoltExtension sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Row.
-
In the Nominal Piping Diameter column, type the NPD for which you want to define bolt extensions.
-
In the Nominal Piping Diameter Units column, type the units for the NPD. For example, type mm or in.
-
In the Pressure Rating column, type the pressure rating for which you want to define bolt extensions.
-
In the End Preparation column, type the end preparation code for which you want to define bolt extensions.
-
In the End Standard column, type the end standard code for which you want to define bolt extensions.
-
In the Standard Bolt Extension for Studs column, specify the length of exposed threads for studs. Be sure to include the units, in or mm, when specifying this value.
-
In the Standard Bolt Extension for Machine Bolts column, specify the length of exposed threads for machine bolts. Be sure to include the units, in or mm, when specifying this value.
-
Save the Piping Specification.xls workbook.
-
Valid end preparation codes are listed in the AllCodeLists.xls workbook on the EndPreparation sheet in the Codelist Number column.
-
Valid end standard codes are listed in the AllCodeLists.xls workbook on the EndStandard sheet in the Codelist Number column.