Pump Nozzle - CADWorx - Help

CADWorx Equipment

Language
English
Product
CADWorx
Subproduct
Equipment
Search by Category
Help
CADWorx Version
22

Mouse Icon Toolbar: EQP Nozzle ICON

Specifies the parameters for the pump nozzle.

This component cannot be created by itself. It must be attached to the following component:

Description

Specifies an alphanumeric description for the component. This description is visible even when the component is collapsed in the grid.

Distance

Specifies the distance from the bottom of the component to which this component is attached. Click Ellipsis ICON to display the Nozzle placement dialog box.

Nozzle Details

Displays the standard nozzle details. Click Ellipsis ICON to display the Nozzle details dialog box.

Layout Angle

Specifies the pump nozzle layout angle.

Length

Specifies the distance from the starting point to the ending point of the component.

Suction Side

Specifies the nozzle suction side.

Direction

Specifies the nozzle direction.

Nozzle placement Dialog Box

Specifies advanced options for nozzle placement. A figure on the dialog box displays the values. This figure changes based on the type of component to which the nozzle is attached.

(A) Distance

Specifies the distance from the bottom of the component to which this component is attached. When the Nozzle direction box (enabled only for a nozzle on a cone) is set to Apex, the Distance box becomes the radial distance of the nozzle from the centerline of the cone.

(B) Lateral angle

Specifies the nozzle lateral angle.

Rotation angle (Y)

Specifies the rotation angle about the Y-axis.

Rotation angle (X)

Specifies the rotation angle about the X-axis.

Rotation angle (Z)

Specifies the rotation angle about the Z-axis.

Centerline Distance

Specifies the component centerline distance.

(C) Offset distance

Specifies the offset distance from the center of the parent component.

(D) Center to face distance

Specifies the component face distance to the center of the parent component.

(E) Layout angle

Specifies the angle between the component centerline and the X-axis.

Nozzle direction

Specifies the component direction.

Nozzle Details Dialog Box

Specifies standard nozzle parameters.

The lists for Diameter, Flange rating, Flange type, and Schedule are populated based on the entries of the NozzleDropDown.TBL file located in the [Product Folder]\Equipment\System folder.

Nozzle basis

Specifies whether you are using nominal or actual parameters. When you select Nominal, Equipment provides a look-up system for flange dimensions and schedule information.

Diameter

Specifies the diameter of the component.

Schedule

Specifies the schedule rating for the nozzle.

Wall thickness

Specifies the component thickness.

Nozzle extension

Indicates whether a nozzle extension (elbow) is included. Click Ellipsis ICON to display the Nozzle extension dialog box.

Nozzle material

Displays the Select Item dialog box, which lets you select the material from the list. For more information, see Select Item Dialog Box. The Select Item dialog box uses the file specified by the MaterialFile configuration file variable. For more information, see MaterialFile.

Flange type

Specifies the type of nozzle flange. If you set this value to N/A, then you can manually specify the Flange thickness and Flange OD values. For Flange type values other than N/A, the software uses the dimensions from the FlangeImperial.DAT or FlangeMetric.DAT file. These files are located in the [Product Folder]\Electrical\System folder.

Flange rating

Specifies the nozzle flange rating.

Flange thickness

Specifies the component thickness.

Flange OD

Specifies the component outer diameter.

Flange material

Displays the Select Item dialog box, which lets you select the material from the list. For more information, see Select Item Dialog Box. The Select Item dialog box uses the file specified by the MaterialFile configuration file variable. For more information, see MaterialFile.

Thread/Engagement length

Specifies the nozzle end point location. This end point provides a snap location for any component attached to the nozzle.

Nozzle reinforcing pad

Indicates whether a reinforcing pad exists. Click Ellipsis ICON to display the Nozzle Pad dialog box.

Nozzle Insulation

Indicates whether insulation exists. Click Ellipsis ICON to display the Insulation dialog box.

Applicable Gaskets

Specifies the code to insert a gasket on the nozzle when you add a component containing Applicable Gaskets or Applicable Bolts in CADWorx Plant. The code that you type in the Applicable Gaskets box must match a code assigned to a gasket in the CADWorx Specification Editor. For more information, see Assign gaskets and bolts to equipment nozzles. You can also find information in the New and Edit Component Pane, and Selection Codes topics in the CADWorx Spec Editor User's Guide.

Applicable Bolts

Specifies the code to insert a bolt on the nozzle when you add a component containing Applicable Gaskets or Applicable Bolts in CADWorx Plant. The code that you type in the Applicable Bolts box must match a code assigned to a gasket in the CADWorx Specification Editor. For more information, see Assign gaskets and bolts to equipment nozzles. You can also find information in the New and Edit Component Pane, and Selection Codes topics in the CADWorx Spec Editor User's Guide.