Start a nozzle schedule at a specific counter - CADWorx - Help

CADWorx Equipment

Language
English
Product
CADWorx
Subproduct
Equipment
Search by Category
Help
CADWorx Version
20.2
CADWorx Structure Version
4.2
  1. Type NSCHSINGLE or NSCHTOTAL.

    Select objects.

  2. Select the nozzle.

    Enter tag option [Counter/Manual placement/Automatic placement].

  3. Type Counter.

    Enter tag starting counter <1>.

  4. Type the starting number for the counter, or press Enter to accept the default.

    Placement of tags [Manual/Automatic].

  5. Follow the prompts for manual or automatic placement of the schedule.