Automatic process data - CADWorx - Help

CADWorx P&ID

Language
English
Product
CADWorx
Subproduct
P&ID
Search by Category
Help
CADWorx Version
22

You must use an external database to complete these steps.

  1. Click Setup on the Process Lines panel.

  2. Select System On (Dynamic Size/Spec).

  3. Add categories and separators as needed.

  4. Select a category, and then assign a value in the Default value box.

  5. Click OK.

  6. Click Pumps Icon Pump.

  7. Select a pump, and then click OK.

  8. Click to place the pump in the drawing, and then click to place the tag information.

    Pump in P&ID

  9. Click Vessel Icon Vessel, and add a vessel in the drawing.

  10. Select a vessel, and then click OK.

  11. Click to place the vessel in the drawing, and then click to place the tag information.

    Pump and Vessel

  12. Click Major Primary , and draw a line between the pump and the vessel.

    You can change the color of the major primary line in the Layers.

    Pump, Vessel, and Line

  13. Click Tag Line .

  14. Select the major primary line.

    Selected Line Pump and Vessel

  15. Click to place the tag.

  16. Click to rotate the tag.

    The software places the tag, and adds the line number to the Tag value.

    Taged line

  17. Double-click the process line.

  18. Click Process Data.

    The Process From, Process To, Actual From, and Actual To boxes display the correct values.