Sanitary Lateral Reducing Vertical - CADWorx - Help

CADWorx Plant

Language
English
Product
CADWorx
Subproduct
Plant
Search by Category
Help
Isogen Version
15
Smart Isometrics Version
8
Spoolgen Version
10
CADWorx Version
22

Mouse Icon Sanitary toolbar: Sanitary Lateral Reducing Vertical

Keyboard Command line: VLARE

Places a 45 degree sanitary reducing lateral with the main normal to the X-Y plane. The center of the lateral is placed at the start point by default.

last point

Starts the component at the last point of the previously-created component.

Up

Places the branch of the lateral in the positive Z direction.

Down

Places the branch of the lateral in the negative Z direction.