Mouse Icon Thrd/SW Fittings toolbar: Thrd/SW Lateral Vert

Keyboard Command line: VLATS/VLATT

Places a 45 degree threaded/socket lateral with the main normal to the X-Y plane. The center of the lateral is placed at the start point by default.

last point

Starts the component at the last point of the previously-created component.

Up

Places the branch of the lateral in the positive Z direction.

Down

Places the branch of the lateral in the negative Z direction.