Default value: 1
Allowed values: 0 through 4

Specifies the layers for top works component placement.

  • 0

Top works are not added to the valve even if a top works file is set in the specification file.

  • 1

Top works are added to the valve. The top works solid is combined with the valve solid to create one solid.

  • 2

Top works are added to the valve. The top works solid is grouped with the valve solid and center line. The top works solid is placed on the same layer as the valve solid.

  • 3

Top works are added to the valve. The top works solid is grouped with the valve solid and center line. The top works solid is placed on a layer set from the CADWorx layer settings.

  • 4

Top works are added to the valve. The top works solid is grouped with the valve solid and center line. The top works solid id placed on a layer set from the CADWorx layer settings. The layer name is derived by appending the valve layer name and the top works layer name. For example, when the valve is on layer _150, and the top works layer name is TOP, the top works solid is on layer _150TOP.