Apply Tab (CADWorx Insulation View Palette) - CADWorx - Help

CADWorx Plant

Language
English
Product
CADWorx
Subproduct
Plant
Search by Category
Help
Smart Isometrics Version
8
Spoolgen Version
10
CADWorx Version
20.2
CADWorx Structure Version
4.2

Controls parameters for applying configurations to CADWorx components.

For most CADWorx components, insulation is approximated with the use of single or multiple CAD platform cylindrical components.

Available Configuration

Displays the currently saved insulation configurations in the current drawing.

Remove

Removes the highlighted row in the grid from the current drawing.

Select Mode

Select on screen

Indicates that you will select components in the drawing window.

Line number

Indicates that you will select components by line numbers.

Insulation Mode

Data/Graphics

Adds both the insulation graphic and data.

Data Only

Adds only the insulation data and no graphics.

Insulation

Add

Adds the insulation currently selected in the Available Configuration grid to components in the drawings. You are prompted to select CADWorx components. If any of the selected components are already insulated, this action is skipped.

Modify

Modifies existing insulation graphics and data.

Remove

Removes existing insulations graphics and data.

Refresh

Generates the graphics from the insulation data stored in the component's centerline. Use this option if insulation graphics were deleted or lost.

Graphics

Add

Adds insulation graphics to components that have had their graphics removed. The data previously stored in the components is used to generate the graphics.

Remove

Removes the graphics from the selected components. The insulation data remains. These components do not show the insulation solid even if you later click Refresh.

Visibility

Isolate

Isolates insulation graphics by either selecting components on screen or by selecting line numbers from the list.

Hide/Show

Hides or shows the insulation graphics by selecting components on screen or by selecting line numbers from the list.

Show All

Shows all objects that have been previously hidden in the current drawing.

Report

Creates a complete report, in HTML format, about all of the insulation components in the model. The report is itemized by the different types of insulation data and calculates the total weight, volume, and length.

Filter

Filters the list of line numbers using wild cards. For example, type *25-1B* to limit the line number list to line numbers with 25-1B as part of the name. The text filter occurs regardless of where the text is in the line number name.

Edit

Displays the Insulation Global Edit <number> Objects dialog box so that you can edit the insulation data for all components having the selected insulation configuration.

Right-Click Menu

In Line Number selection mode, a right-click menu is available with additional options. The right-click menu changes what displays in the edit box.

Select All / Clear All

Selects or clears all line numbers in the list.

List Insulated Line Numbers

Lists only insulated line numbers.

List Un-Insulated Line Numbers

Lists only uninsulated line numbers.

List Data Only Line Numbers

Lists line numbers that have insulation data but no insulation graphics.

List Un-Insulated Components

Lists only uninsulated components.

List All

Refreshes the list.

Modify

Replaces the selected insulation data with the highlighted insulation in the Available Configuration grid. This change applies to all components in the selected line number.

Remove

Removes the insulation from all components in the selected line number.

Insulation Global Edit <number> Objects Dialog Box

Controls parameters for editing the insulation data on multiple objects. This dialog box applies the settings to all of the selected objects.

Thickness

Displays the insulation thickness value. You cannot edit this value.

Density

Specifies the insulation density value. Type numeric values greater than zero. You can also select an existing value. The density is used to calculate the insulation weight by multiplying it with the insulation volume. This parameter is required to create an insulation configuration.

  • In Imperial units (Imperial pipe size / Imperial dimensions), this value has units of lb / in3.

  • In mixed metric (Imperial pipe size / metric dimensions) the value has units of g / cm3.

  • In metric (metric pipe size / metric dimensions), the value has units of g / cm3.

Mastic

Specifies the mastic description. This is an optional value.

Heat Tracing

Specifies the heat tracing description. This is an optional value.

Insulation

Specifies the insulation description. This is an optional value.

Jacketing

Specifies the jacketing description. This is an optional value.

User