Add a new end type table - CADWorx - Reference Data

CADWorx Spec Editor

Language
English
Product
CADWorx
Subproduct
Plant
Search by Category
Reference Data
CADWorx Version
20.2
  1. Click End Type Table Add End Type Icon Spec Editor on the Add Table panel. Alternatively, right-click End Type Tables in Catalog Data, and then select Add End Type Table Add End Type Icon Spec Editor.

    The New End Type Table dialog box displays.

  2. Type the name of the new table in the Name box.

  3. Select the end type from the Type list.

  4. Select the Size Table.

    Click the Size Table ellipsis to select the main sizes for this end type table. Alternatively, use Add MAINSIZE in the Main Table List View.

  5. Type a Part Number.

  6. Select a default Isogen Symbol from the list.

  7. Select selection codes from the Applicable Gaskets list, or type a code in the box.

  8. Select selection codes from the Applicable Bolts list, or type a code in the box.

    You must have the Selection Codes defined in the gasket and bolt components. For more information, see Selection Codes, Selection Codes Tutorial, Set selection code defaults, and Assign selection codes to components without catalog defaults.

  9. Type the Component Class.

  10. Type the Temperature Rating.

  11. Type the Pressure Rating.

  12. Type the Description.

  13. Click OK.

    The new end type table displays in the Main Table List View and adds to Catalog Data under the End Type Tables folder.

  14. Click File > Save to save the changes to the catalog.