Displays the Miscellaneous Data Options dialog and allows you to select which portions of the results or of the output are reported in Miscellaneous Report. Select the options you want to print or view, and then click OK to display the report.

The following report options are available:

Bends SIF

SIF and flexibility data for bends.

Allowables

Allowable stress summary.

Tees SIF

SIF and flexibility data for tees.

B31J provides directional stress intensification factors and flexibility factors. The software uses the highest in-plane or out-of-plane SIF when the piping code defines a stress equation that uses a single SIF. The software uses the flexibility factors for the specified orientation. See B31J Methods.

Reducers

Reducers report.

Nozzles

Nozzle flexibility data.

B31.3 MDMT

Minimum design metal temperature analysis for the brittle fracture of piping according to B31.3.

Pipe Prop #1

Pipe properties report with weights and minimum calculated wall thickness for each element.

Pipe Prop #2

Pipe properties report with weights and minimum calculated wall thickness for each element.

C.G.

Center-of-gravity report.

B.O.M.

Bill of materials.

Wind

Wind input data.

Wave

Wave input data.

Seismic

Seismic input and calculated g factors (magnifiers of gravitational loading).

B31.8 Buckling Check

Stress and strain values to determine buckling and lateral instability for a pipe element according to B31.8-2018 paragraph 833.10.