Weld ID - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

Specifies the weld identifier value. Select 0 - As Welded or 1 - Finished/Ground Flush.

If you specify a value of 1 - Finished/Ground Flush, then the software considers the weld to be ground flush on the inside and out and it calculates the SIF as 1.0.

For more information on how input parameters are used to compute SIFs for girth butt welds, see Mismatch - Average / Weld (d).

This property only applies to:

  • Bonney Forge Sweepolets

  • Bonney Forge Insert Weldolets

  • Butt Welds in the Swedish Piping Codes

  • IGE/TD/12

  • Butt Welds in the IGE/TD/12 code