Cold Elastic Modulus - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

Defines the value of the elastic modulus to be used in code compliance stress cases.

Typical units (depending on your unit system):

  • lb/in²

  • N/mm²

  • KPa

The software uses this value only if no Elastic Modulus is given for the ambient (70° F) temperature. This value is used for metal materials only.