Flange Outside Diameter (A) - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

Defines the flange outside diameter if an ASME stress calculation for the flange is needed. You can omit this entry if only a leakage check is to be performed.

Typical units (depending on your unit system):

  • in

  • mm

  • cm

This value is required only for ASME stress calculations. It is available in the flange ANSI B16.5/API dimensional database. You can access the flange database properties by pressing Ctrl+F from any data input field in the Flange tab.