Flanges (Input Export Options) - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

Export user specified flange information defined in the input file.

Microsoft Access Table Name: INPUT_FLANGES
Microsoft Excel Section Name:
XML Primary Tag Name:

Data Name

Column Name

XML Tag Name

Flange Pointer

FLANGE_PTR

Flange Location

FLANGE_LOCATION

FLANGE_LOCATION

Flange Evaluation Method

METHOD

METHOD

Flange Class and Material Grade

CLASS_GRADE

CLASS_GRADE

Gasket Diameter

GASKET_DIAMETER

GASKET_DIAMETER

Bold Circle Diameter

BOLT_CIRCLE_DIA

BOLT_CIRCLE_DIA

Bold Area

BOLT_AREA

BOLT_AREA

Flange Yield Stress - Cold (Ambient) Temperature

SY_COLD

SY_COLD

Flange Yield Stress, Operating Temperature 1

SY1

SY1

Flange Yield Stress, Operating Temperature 2

SY2

SY2

Flange Yield Stress, Operating Temperature 3

SY3

SY3

Flange Yield Stress, Operating Temperature 4

SY4

SY4

Flange Yield Stress, Operating Temperature 5

SY5

SY5

Flange Yield Stress, Operating Temperature 6

SY6

SY6

Flange Yield Stress, Operating Temperature 7

SY7

SY7

Flange Yield Stress, Operating Temperature 8

SY8

SY8

Flange Yield Stress, Operating Temperature 9

SY9

SY9

Flange Temperature

TEMPERATURE1 through
TEMPERATURE24

TEMPERATURE1 through TEMPERATURE24

Flange Pressure

PRESSURE1 through
PRESSURE24

PRESSURE1 through PRESSURE24

Access and Excel contain a number that identifies on which element they were defined.

INPUT_BASIC_ELEMENT_DATA.FLG_PTR = INPUT_FLANGES.FLG_PTR