The compatible units librarian for XYZ Utility Corp, Inc. defines the following compatible units library records to be used when performing estimation:
Compatible Units Library record |
Labor (Action Type; Trade - Hours required) |
Parts (Part - Quantity) |
Tools (Tool - Hours required) |
Child CUs (Child CU - Quantity) |
---|---|---|---|---|
CU_LIB-01A (Pole) |
Install; Electrical - 2.5 hours Remove; Electrical - 1 hour Abandon; Electrical - 1 hour Transfer; Electrical - 3.5 hours |
Install; Pole - 1 ea. |
Install; Excavator - 1.5 hours Remove; Jackhammer - 1 hour Abandon; Jackhammer - 1 hour Transfer; |
n/a |
CU_LIB-01B (Crossarm) |
Install; Electrical - 0.5 hours Remove; Electrical - 0.25 hours Abandon; Electrical - 0.25 hours Transfer; Electrical - 0.75 hours |
Install; Crossarm - 2 ea. |
n/a |
n/a |
CU_LIB-01C (Transformer) |
Install; Electrical - 3 hours Remove; Electrical - 2 hours Abandon; Electrical - 2 hours Transfer; Electrical - 5 hours |
Install; Transformer - 1 ea. |
n/a |
n/a |
CU_LB-01 (Assembly) |
n/a |
n/a |
n/a |
CULB-01A - 1 CULB-01B - 1 CULB-01C - 1 |
CU_LIB-02 (Bracket) |
Install; Electrical - 0.5 hours Remove; Electrical - 0.25 hours Abandon; Electrical - 0.25 hours Transfer; Electrical - 0.75 hours |
Install; Bracket - 1 ea. |
n/a |
n/a |
CU_LIB-03 (Wire) |
Install; Electrical - 0.5 hours |
Install; Wire - 1 ea. |
n/a |
n/a |
CU_LIB-04 (Site Cleanup) |
Install; General Labor - 5 hours |
n/a |
n/a |
n/a |
It is expected that the organization will invest significant time and resources to prepare a collection or library of compatible units specific to that organization’s needs & business practices.