HxGN EAM parameters are related only to HxGN EAM and do not affect HxGN EAM (Oracle Forms). Set values for HxGN EAM parameters according to the following table.
For more information on setting values for parameters, see Defining installation parameters.
Code |
Description |
Fixed |
---|---|---|
ANALOG |
Analytics logging level. Valid values are: ERROR, WARN, INFO, or DEBUG. |
No |
ANALOGKP |
Number of days to keep Analytics server log records. |
No |
Example: 7 |
||
ANASYNKP |
Number of days to keep Analytics synchronization records. |
No |
Example: 180 |
||
AUTOSAVE |
This code indicates whether to save work automatically when moving from tab to tab in HxGN EAM. Valid values are YES and NO. If set to NO, then HxGN EAM displays a message prompting the user to save their work when moving from tab to tab. |
No |
Example: YES |
||
CANCSTAT |
This code indicates the status used by HxGN EAM when a work order is canceled. You can choose from any equivalent user statuses. |
No |
Example: CANC |
||
DBBUFSIZ |
Cache size for grid query results. |
No |
Example: 500 |
||
DWLABOR |
Indicates whether the data warehouse ETL driver will populate the Booked Labor hours and Available Labor data mart. Valid values are ON and OFF. |
No |
DWMATL |
Indicates whether the data warehouse ETL driver will populate the Daily Material transactions data mart. Valid values are ON and OFF. |
No |
DWORDERS |
Indicates whether the data warehouse ETL driver will populate the Purchase orders and order lines data mart. Valid values are ON and OFF. |
No |
DWPARTS |
Indicates whether the data warehouse ETL driver will populate the Parts and Stores daily values data mart. Valid values are ON and OFF. |
No |
DWSTATUS |
Indicates whether the data warehouse ETL driver will populate the Daily Status Changes data mart. Valid values are ON and OFF. |
No |
DWWARNTY |
Indicates whether the data warehouse ETL driver will populate the Warranty claims accumulating values data mart. Valid values are ON and OFF. |
No |
DWWORK |
Indicates whether the data warehouse ETL driver will populate the Work orders accumulating and daily values data mart. Valid values are ON and OFF. |
No |
EQUIPSTR |
Define which fields will display in equipment structure. Valid values are B, C, or D. Specify B to display both the code and description. Specify C to display only the code. Specify D to display only the description. |
No |
REJSTAT |
This code indicates the status used by HxGN EAM when a work request is rejected. You can choose from any equivalent user statuses. |
No |
Example: REJ |
||
REPCLEAN |
Specifies how long in minutes that report temporary data will remain. |
No |
Example: 240 |
||
REPORTMX |
The maximum number of records that can be returned to the work order, requisition, and purchase order reports in HxGN EAM without causing an error. |
No |
Example: 100 |
||
REPPURGE |
This code indicates the amount of time (in minutes) to keep an HxGN EAM report output file on the server before deleting it. |
No |
Example: 1440 |
||
RTIMEOUT |
This code indicates the amount of time (in seconds) to wait for a report to finish executing before sending it to the report queue. |
No |
Example: 120 |
||
SHOWLOT |
Determines whether lots are used for stock information for parts in HxGN EAM. The default setting for SHOWLOT is Y. If SHOWLOT is set to N, Extended disables the Lot field and it is hidden on forms. |
No |
SRQREP |
This code indicates the number of days to search for similar re- quests. The system flags similar services requests that are repeated. |
No |
Example: 5 |
||
WHSLEEP |
This code indicates the time increment (in hours) between each data warehouse ETL procedure update. The default value is 24. |
No |
WHSTART |
This code indicates the specific time at which to run the data warehouse ETL update (based on the server time). Enter in the format HH:MM, where HH is 24 hour time, MM is minutes. The default value is 2:00 (2AM). |
No |
WSLSUPP |
Contains a comma separated list of supported Language strings that are encrypted. |
No |
WTIMEOUT |
The value specified for this parameter indicates the length of time (in minutes) that the client can remain idle/inactive before the server terminates the user’s session for both HxGN EAM (Oracle Forms) and HxGN EAM. After the server terminates the session in HxGN EAM (Oracle Forms), the system displays a message indicating that the user’s session is being terminated. After acknowledging the message, the server shuts down the HxGN EAM application. After the server terminates the session in HxGN EAM, the form on which the user was working is still displayed. However, when the user tries again to use the system, the system displays a message and returns to the login screen. Example: 15 |
No |