See the following table for Asset Management module options:

Code

Description

Validation Type

Fixed

Valid Values

Default Value

AINVAPP

Determines resolution of the asset when the asset inventory session is approved, and the Observed Physical/Bin Location is NULL. If FOUND, then system sets the Resolution of the asset to "Asset Found". If NOT-FOUND, system sets the resolution of the asset to "Asset Not Found". If BLOCK, the system does not allow approving the session if any unresolved assets exist.

Code

‘-‘

FOUND, NOT-FOUND, BLOCK

FOUND

GENEQMAX

Determines the threshold at which the equipment generation process starts in asynchronous (background) mode. If Generate Count is higher than this setting, the process runs asynchronous and the process is queued. Otherwise the process runs synchronous and the user must wait for the process to finish.

Integer

'-'

1, 999999

100

GENEQWRN

Prevents the start of the equipment generation process when warnings still exist. If set to YES the system asks the user to start the generation process and ignore the warnings. If set to NO, the system does not allow the user to start the generation process.

Code

'-'

YES, NO

NO

GENEQPMR

Prevents the equipment generation process from creating PM work orders if PM revision control is active.If set to YES, the system generates PM work orders without asking for approval. If set to NO, the system will not generate PM work orders. If set to WARNING, the system raises a warning message during the Preview generation.

Code

'-'

YES, NO, WARNING

NO

METRDOWN

Determines if meter readings will roll down to child equipment with the same UOM and with a meter type that indicates it is a child. If set to AC, the reading will roll down to all qualifying children on any level. If set to DC, the reading will only roll down one level to qualifying children.

Code

'-'

AC, DC

AC

RCMPREFS

Determines if extra features for the setup of the RCM tree will be available. If set to OFF, the system offers no extra features. If set to FDSC, the system will format the description using a noun, a verb, and an optional complement. This setting is only available for failure mode descriptions. If set to FMEF, the system will show the effect indicator and consequence fields for a failure mode. If set to FULL, all extra features are active.

Code

'-'

OFF, FDSC, FMEF, FULL

OFF

SRSTSYNC

Determines if the system should maintain a structure record between the header equipment and the segment or the route, if a record is inserted or deleted on the Segments or Routes tab of the equipment screens. If set to I, a structure record will be created at insert. If set to D, the structure record will be removed at delete. If set to ID, the structure is maintained both at insert and delete. If set to OFF, the system will do nothing.

Code

‘-‘

OFF, I, D, ID

OFF

WSSELECT

Determines the default value of the Include in Move check box on the Associations tab of the Workspace Moves screen. Set to YES to default the selection of the check box. Set to NO to clear the check box by default.

Code

'-'

NO, YES

YES