Associate aspects with equipment or categories. For example, specify a category of vans or a particular van, and then associate it with the inspection aspect of measuring tire tread.
To define equipment inspection aspects:
-
Select Work > Inspections > Monitored Data.
-
Select the equipment, equipment class, or equipment category for which to enter inspection aspect information, and then click the Aspects tab.
-
Click Add Aspect. Origin is automatically populated.
-
Specify this information:
Aspect - Specify the inspection aspect with which to associate the monitored data object.
Method - Specify the inspection method for the aspect as necessary.
Nominal Value - Specify the starting value or normal value and unit of measure for measurements on this aspect. For example, if a new pipe’s wall thickness is 3 mm, the nominal value is 3 and the unit of measure is mm.
Min. Extreme - Specify the minimum extreme value beyond the operating specifications for the aspect.
Min. Critical - Specify the lowest possible value for the aspect.
Min. Tolerance - Specify the minimum percentage of critical value for the aspect.
Min. Std. WO - Specify a standard work order to restore normal operating conditions when the minimum critical value is reached.
Min. PM - Specify a preventive maintenance work order to restore normal operating conditions when the minimum critical value is reached.
Max. Extreme - Specify the maximum extreme value beyond the operating specifications for the aspect.
Max. Critical - Specify the highest possible value for the aspect.
Max. Tolerance - Specify the maximum percentage of critical value for the aspect.
Max. Std. WO - Specify a standard work order to restore normal operating conditions when the maximum critical value is reached.
Max. PM - Specify a preventive maintenance work order to restore normal operating conditions when the maximum critical value is reached.
-
Click Submit.
You cannot remove aspect records that are indirectly associated with the monitored data object.