SG-1765 CLONE - Work Orders | Parts - Used field showing wrong quantity when issuing the same part number

 Description 

The same part is issued twice via activity 1 and via activity 2 on the same work order. This is done in the Parts tab of the wo. That tab propopes the Used field. It is associated to the chosen activity, but it will show the total qty of used parts if the same part is issued.

*Actual results*

Used field shows total qty

*Expected results*

Used quantity linked to the issued qty on the activity

*Steps to reproduce*

1. Go to work orders screen and create wo with two activities

2. Open the parts tab

3. Issue part X on activity 1

4. Issue part X again but on activity 2

5. Checkout the Used field (activate with screendesigner).

See attached screenshot.