EAM-54218 CLONE - Configuration Manager - Export | Preview | Export - Export of single user group with patch 202107 is not complete, missing records - HxGN EAM - Version 12.0 - Hexagon

HxGN EAM Resolved Issues for 2022

Language
English
Product
HxGN EAM
Search by Category
HxGN EAM Version
12

EAM-54218 CLONE - Configuration Manager - Export | Preview | Export - Export of single user group with patch 202107 is not complete, missing records

 Description 

After patch 202107 where EAM-52653 should have been fixed, when we now export instead of all R5PAGELAYOUT records being exported, too few R5PAGELAYOUT records now get exported.

The process is very slow (unchecking the user group records under Preview, and checking the correct user group records).

When we finally are able to export the session, and we compare the record count in the xml created and in the database, we can see differences. For example when we have 80646 records in R5PAGELAYOUT for the user group, the header xml only shows

<tableCount tableName="R5PAGELAYOUT">20509</tableCount>

Steps to reproduce:

(Configuration of R5Jobparamvalue, value of PREVIEW=P)

I also change the transactiontimeout to 3000, as the processes in some steps take a long time.

Configuration Manager - Export - Unselect all.

Select User Groups and Permissions, Page Layout and Status Authorizations.

Click on Preview.

When preview is ready, go to Record view select our export ID, and go to Preview tab.

Unselect all and save. (this takes a long time)

When eventually saved, select only the record for our group, in my case RE-MTZ-X.

Click Export.

Under Status, the status changes to Submitted, then after a while Started, and then Finished.

Now click on the link, and open the header xml.

Compare these counts with counts in the database, and see the differences.

Also via the screens we can see that screen designer page layout has not been copied.

Actual results: Not all selected records get exported for our selected user group.

Expected results: All selected records get exported for our selected user group.

EAM-54221 CLONE - Work Orders | Calibrations - Negative readings are not working in Calibration records entries