EAM-54483 CLONE - Alert Management - Work orders not generated when PPMSTAT = A (with UCOLANG and DEFLANG = NL)

 Description 

When an Alert Management is set up to automatically generate work orders, nothing happens in EAM with UCOLANG and DEFLANG = NL , when PPMSTAT = A.

Only when the PPMSTAT is changed to W, a work order is generated.

PPMSTAT can only have A (or R) as a value, so we cannot use W. Value W also causes problems in PM schedules.

UCOLANG and DEFLANG = NL

PPMSTAT=A

1. Alert Management - Create an alert with Grid name BAL016. Dataspy All Work Orders, grid key 1 workorder.

Frequency 5 minutes. Next date systime+ 5 minutes.

2. Alert Management - Grid parameters, add necessary parametesrs, Generate through 31, add your organization.

3. Alert Management - Generate Work Orders - PM Schedule / MP Type = Fixed / Variable PMs

4. Activate the alert.

5. Create a PM schedule of type Fixed with equipment for the alert organization, due date today.

6. ALRT job needs to be active and running.

You should see the WO candidate now in Alert record view - Preview Grid.

Nothing happens although the alert next run is updating.

Now change the PPMSTAT=W

WO gets generated.

Actual result - WO does not get generated with PPMSTAT=A

Expected result - WO gets generated with PPMSTAT=A