You may want to use PSI data, such as D&R information, in workflows. For example, the Proposed Changes item can be added to checklists to identify proposed value and setting changes. For more information about this checklist item and others, see Creating Checklists for Workflows.

To allow Integrity to connect to PSS:

  1. Edit the IntegrityMOCRoot.xml file. This file is located in the root folder of the application, such as C:\PAS\Integrity\.

  2. Find the following tags in the IntegrityMOCRoot.xml file:

    <PSSWebServerName> </PSSWebServerName>

  3. Specify the name of the PSI web server in these tags, such as <PSIWebServerName>ServerName</PSIWebServerName>
    where ServerName is the computer name. In some cases, you may need to specify the IP address.

  4. Save and close the IntegrityMOCRoot.xml file.