In the tree view, click Piping > Piping Specification > Piping Materials Classes.
-
In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Service Limits.
-
Click the Insert Row Command to insert a blank row in the grid view.
-
In the Temperature column, type the temperature service limit.
-
In the Pressure column, type the corresponding pressure service limit.
The Service Limits sheet in the Piping Materials Class.xls workbook corresponds to the Service Limits node. See Piping Reference Data.