Load edge definitions to the Smart 3D catalog schema database - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
13
  1. Open the edge registry file, EdgeEntry.xls.

    You must be using Microsoft Excel 2007 or newer.

  2. Create an entry for each edge definition. Specify the name of the edge definition, the catalog package in the catalog schema database into which the edge definition is loaded, and the complete path to the edge definition.

    • If there is already an entry for the edge definition, check the Column A cell preceding the Edge Name. If it reads D, then you can change it to A and verify that the Package Name information and the complete path to the edge definition file are correct. If it reads A, an edge definition of the same name is already in the database. You cannot load this edge definition unless you delete the edge definition of the same name from the database.

    • User-defined edge definitions can only be loaded into the default UserDefinedPackage catalog package.

    SHARED Tip To delete edge definitions from the database, type D in the Column A cell preceding the Edge Name for each edge definition to delete. The Edge Loader can process loading and deleting edge definitions at the same time.

  3. Save your changes, and close the edge registry file.

  4. Double-click EdgeLoader.

    The Edge Loader Dialog displays.

  5. In the Provider Type box, specify the database provider. You can select MSSQL Server or Oracle.

  6. In the Server box, specify the database server where the catalog database and catalog schema database reside.

  7. In the Catalog Schema box, specify the catalog schema database into which to load the edge definitions.

  8. If you want to update the catalog database views with the edge definitions that are loaded after the loading processing completes, select Update Catalog Database View, and specify the catalog database in the Catalog Database box.

    After loading the edges, you must update the Model views and regenerate the Reports database. You can use the View Generator utility to update the Model views. See the Project Management User’s Help.

  9. In the Registry File box, specify the complete path to the edge registry file, EdgeEntry.xls. You can click Browse to browse to the file location.

  10. In the Log File box, specify a log file for tracking the loading processing.

  11. Click Load for the software to load the edge definitions to the Smart 3D catalog schema database.