Error code 104 - unspecified error description (Foundations) - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

Error code 104 - unspecified error description

Severity

High

Detailed Description

A foundation exists but has no corresponding entry in the CoreSpatialIndex table

Possible Cause

A component based foundation was placed in the previous version of the software.

Possible Impacts

Foundations cannot be selected through the volume filters.

What You Should Do

Run the DBI script to correct these foundations. The script accumulates the range of all of the foundation's outputs and assigns it to the parent foundation.