A BracketByPlane PlateSystem's point is not an input to the symbol.

Severity

Crucial.

Detailed Description

A BracketByPlane PlateSystem requires two points for proper placement on the identified supports. These points must also be inputs to the symbol. The relationship to the symbol is missing.

Possible Cause

Unknown.

Possible Impacts

The geometry and display of the PlateSystem will not be correct. This problem can affect other related objects.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the BracketByPlane PlateSystem, select the points, and make any other necessary modification. Or, perform a recomputation on the PlateSystem.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.