A PlateGeometry does not have a related PlanningSplitAE - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

A PlateGeometry does not have a related PlanningSplitAE.

Severity

Crucial.

Detailed Description

A plate geometry does not have a related Planning Split active entity (AE): Missing the StructOperation_RSLT1 relationship to PlatePlanningSplit_AE for the light PlateGeometry of the PlatePart, or to GeneratePlatePart_AE for the new immediate_thickening code.

Possible Cause

Unknown.

Possible Impacts

Unknown.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the object, and modify it, if necessary. Or, select the object, and perform a re-computation to update it.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.