Message
A profile part does not have a related ProfilePartReportData object.
Severity
Crucial.
Detailed Description
Missing the ReportData relationship to ProfilePartReportData for StandAloneStiffenerPart and un-split (EdgeReinforcementProfilePart, StiffenerPart, BeamPart). "Un-split" in this case means it is STRUCT_ACTIVATED.
Possible Cause
Copying a system before Version 4.
Possible Impacts
The weight and center of gravity (CoG) may not be calculated and will be invalid because the report data does not exist.
What You Should Do
-
Open the model.
-
In the Molded Forms task, select the object, and modify it, if necessary. Or, select the object, and perform a re-computation to update it.
-
Re-run the Check Database Integrity custom command and the DBIntegrity report.
-
If the object is still posted, contact Smart 3D Support.