Cable Nozzle does not have proper orientation values.

Severity

Normal.

Detailed Description

Cable nozzles should have the proper orientation vectors declared. The orientation vectors should not be persisted as NULL values as we specify 1,0,0 for orientation and 0,1,0 for radial orientation vectors (DistribPortType_CABLE).

Possible Cause

Undetermined workflow in the Place Nozzle command.

Possible Impacts

The cable nozzle might be displayed incorrectly.

What You Should Do

Run the Clean Database custom command, which updates the orientation vector and the radial orientation vectors with the default values.