Message

Equipment does not have a system parent.

Severity

High.

Detailed Description

The equipment is not related to its system parent anymore. This situation is unexpected.

Possible Causes

  • The cause at run time is currently unknown.

  • The cause could be external, for example, database manipulation.

Possible Impacts

  • Some commands may work incompletely.

  • You cannot copy the equipment to the catalog. If you try, an error appears: No required inputs were generated. If inputs were required, this may be a problem. When you click OK, the software displays an application error.

  • Equipment reports are possibly erroneous or inaccurate.

  • It is impossible to retrieve equipment using filters and style rules based on systems.

What You Should Do

If the problem is local to one or a few equipment:

  1. Open the model.

  2. Delete the equipment.

  3. Save the session.

  4. Refresh all session files with a workspace including the equipment.

If the problem is widespread on all equipment:

  1. Restore your most recent backup using the Project Management task.

  2. Refresh your session files.