The BracketByPlane definition point PG does not match the BracketByPlane PG - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13

Message

The BracketByPlane definition point PG does not match the BracketByPlane PG.

Severity

High.

Detailed Description

The defining points needed for the BracketByPlane plate system have a different Permission Group (PG) than that of the BracketByPlane plate system. The defining points need to have the same permission group as the plate system.

Possible Cause

Unknown.

Possible Impacts

You cannot manipulate the object itself or other objects related to it.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. In the software, click Tools > Custom Commands, and run the Clean Database custom command.

  3. Select the object(s) to be repaired.

  4. Click Clean Now.

  5. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  6. If the object is still posted, contact Smart 3D Support.