  1. Open the CableWay.xls workbook.

  2. Select the CableWay Nominal Sizes sheet.

  3. Select a row after the Start keyword but before the End keyword and click Insert > Rows.

  4. In the Spec Name column, type a name for the cableway specification.

  5. In the Section Name column, type the cross section names that you want to define for the specification.

  6. Type A in the first column of the added rows.

  7. Save the workbook and exit.

  8. Bulk load the workbook in the Add/Modify/Delete mode.

The cableway specification must be defined on the Cableway Spec sheet.