Edit cross section properties - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D HVAC

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Help
Smart 3D Version
13.1
  1. Click Properties on the horizontal ribbon while routing a duct run.

  2. On the Duct Properties Dialog, click the Cross Section Tab.

  3. Select the shape of duct that you need by using the Cross Section box.

  4. Type appropriate dimensions for the selected cross section in the Dimensions boxes. Be aware that the software does not recalculate dimensions of existing duct automatically.

  5. If needed, switch the local axis of the duct associated with the width axis of the offset cross section by clicking the Orientation button. The Orientation icon changes to indicate if the current value is set parallel or perpendicular to the width dimension of the U axis. By default the width is associated with the U axis.

  6. Type the number of degrees to change the angle of the selected cross section in the Angle box.