Join two existing ducts - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D HVAC

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Help
Smart 3D Version
13.1

Show me

Join_Ducts_ExtendRoute

  1. Click Quick Route Command on the vertical toolbar.

  2. Select an end feature from which to extend the duct.

  3. Select a terminating end feature or a nozzle.

    The software displays all possible path options based on the location of the selected features. You can navigate through the path options and view the dynamic computed graphics.

  4. On the Path Options menu, select an option that you want. You can click the option or press ENTER to confirm your selection.

    By default, the software considers the highlighted option as your selection.

  5. If necessary, select an appropriate run from the Run drop-down list, or proceed to Step 6.

    • Select <Select from D&ID> to select a run from the P&ID.

    • Select <Select Graphically> to select an existing run in a graphic view or in the Workspace Explorer.

    • Select <New Duct Run> to create a new duct run to route. See New Duct Run Dialog.

    • Select More... to select a duct run that is associated with a different duct system. See Select Duct Run Dialog.

  6. Click Finish to join the two end points along the selected path.

    If the selected path results in skews, then the software prompts you with a warning message.

    1. Click No to undo the current path selection.

    2. Select another path option, and then click Finish.