Reviews and modifies end features or components.
Properties
Opens a dialog box with properties for the selected feature. Allows you to review the properties of the selected feature and change the value assigned to a property.
Move From
Defines the origin of the move vector. If you do not define a starting point, the current location of the end feature is assumed to be the starting point.
Move To
Defines the termination point of the move vector.
When you move, or modify a route object in HVAC, Electrical, or Piping, Smart 3D treats any unfinished ends as free end features. An unfinished end is an end with mating parts or a logical data connection with one logical port. You can reconnect using these free end features. This behavior allows you to reuse existing mating parts and connections and reduces wait times.
Plane
Plan Plane
Defines the work surface as the XY plane at the depth of the active end. You also can press CTRL+1 to select this option.
Elevation Plane: East-West ( Z Plane: X-Axis)
Defines the work surface as the XZ plane. You also can press CTRL+2 to select this option.
Elevation Plane: North-South ( Z Plane: Y-Axis)
Defines the work surface as the YZ plane. You also can press CTRL+3 to select this option.
Plane by Turn/Branch
Defines the work surface as the plane defined by an existing turn or branch. You select the turn or branch to set the plane. You also can press CTRL+4 to select this option.
Plane by Three Points
Defines the work surface using three points that you define. You also can press CTRL+5 to select this option.
No Plane
Clears any work surfaces. The software does not project points that you place to any plane. You also can press CTRL+6 to select this option.
Run
Specifies the name of the duct run associated with the branch. You can select another run from the list if necessary.
<New Duct Run> displays the New Duct Run dialog box. Use this option to create a new duct run.
<Select Graphically> allows you to select an existing run in a graphic view, or the Workspace Explorer.
<Load More Runs> loads all the runs that belong to the parent system. This option is not available after you load all the runs, or if the parent system contains less than 200 runs.
More displays the Select Duct Run Dialog. Use this option to select a duct run that is associated with a different ducting system.
Part
Defines the part assigned to the end feature.
Lock
Turns on or off locking for the angle. If the angle is locked, the angle at the other end of the leg is fixed at the value in the Angle field.
Leg Angle
Defines the angle of the leg end feature.
Rotate
Allows you to rotate the end feature.
Rotation Angle
Defines the rotation angle for the end feature.
Length Lock
Locks or unlocks the Length box.
Length
Defines the length for the end feature. You can enter any value needed, provided it does not conflict with the defined specifications. If the Length Lock is unlocked, this box displays the dynamic readout of the current end feature length.
Offset
Defines the distance for offset that the software uses during feature placement. The reference is centerline, width, or depth). The route plane does not have to be active to locate the offset from the plane point.