The following properties are used for the part selection rule and the location of the ports. You must enter the values to get a correct port location and for the selection of clevis part based on part selection rule.
For these properties, the default unit of distance is "mm". Specify "in" at the end of dimensional value to use inches.
IJUAhsRodDiameter::RodDiameter
Specifies the outside diameter of the rod that attaches to the eye nut. This value is used only for part selection rules for choosing the correct clevis part and has no impact on creating graphics.
IJUAhsRodTakeOut::RodTakeOut
Specifies the distance between the pin port and the port at the end of the rod. This value represents the amount that the clevis takes out of the overall rod lengths.
IJUAhsOpening1::Opening1
Specifies the distance from the pin centerline to the inside face of the end nut.