Basic Dummy Leg Properties - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
Hangers and Supports
Search by Category
Reference Data
Smart 3D Version
13

IJUAhsBotShape::BotShape

Specifies the dummy leg/stanchion shape to use.

IJUAhsTopShape::TopShape

Specifies the dummy leg/ stanchion to use. TopShape is optional.

IJUAhsLength::Length or IJOAHgrOccLength::Length

Specifies the total height of the dummy leg from the pipe centerline to the bottom of the centerline including all the plates. Length must be positive and greater than half the Diameter1. If length is not specified for IJOAHgrOccLength::Length, then the part is of variable length.

IJOAhsDiameter1::Diameter1

Specifies the diameter of the pipe. Diameter1 is optional but must be greater than zero.

IJOAhsElbow::ElbowRadius

Specifies the radius of the elbow. ElbowRadius is optional and must be greater than zero. If you do not specify this parameter, the dummy leg is made for a straight pipe.

IJOAhsElbow::FaceToCenter

Specifies the face to center distance of the elbow. For a short tangent elbow, FaceToCenter is same as ElbowRadius. FaceToCenter is optional but and must be greater than zero. If you dot specify this parameter, the dummy leg is made for a straight pipe.

IJOAhsOffset1::Offset1

Specifies the offset from the pipe centerline to the dummy leg centerline. Offset1 is required and can be either positive or negative. If you do not specify this parameter, the software uses zero as the default offset. Offset1 is only applicable for elbows.

IJUAhsRepadShape::RepadShape

The repad shape has not been implemented for the Dummy Leg SmartPart. This property can be ignored. If you require a repad for your dummy support, you will need to add it as a separate part in your standard support. See Reinforcement Pad (Repad) for details on how to create a new repad part.

IJUAhsStanchion::IsStanchion

Specifies whether the part is a stanchion. If IsStanhcion is set to Yes - 1, then both the bottom and top shapes are stanchion shapes. If IsStanhcion is set to No - 2, then one of the shapes is a dummy leg. If the part has bottom and top shapes, the top should be a dummy leg shape. If the part has only a bottom shape, then the bottom shape should be a dummy leg shape.

IJUAhsOffset2::Offset2

Specifies the offset with which the top shape and the bottom shape overlap each other. Offset2 must be greater than or equal to zero. If Offset2 is zero, then the two shapes are butted to each other. If Plate1Shape or Plate2Shape are specified, then Offset2 is ignored. The dummy legs butt up against the plates.

IJUAhsStanGap::StanGap

Specifies the distance between the bottom of the pipe and the top of the stanchion shape or load plate. StanGap must be greater than or equal to zero. StanGap is used only when IsStanchion is set to Yes.

IJUAhsMinLen::MinLen

Specifies the minimum length of the dummy leg. If MinLen is not specified, then a default value of -9999 can be used.

IJUAhsMaxLen::MaxLen