ProductionCheck_DistanceBTWHoleAndHole - Intergraph Smart 3D - Update 2 - Reference Data - Hexagon

Intergraph Smart 3D Hole Management Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Hole Management
Search by Category
Reference Data
Smart 3D Version
14

This rule checks the minimum distance between any two Hole Traces. If the distance between any two Hole Traces is less than 50mm or value prescribed by user, it reports error. The rule is a manual repair type rule, so user need to place the hole traces at the location which maintains at least a minimum distance of 50mm (or the minimum distance as configured) in between them.

Below image illustrates the two Hole traces being placed at a valid minimum distance >= 50mm

The below image describes the hole traces reported with error in production check when they do not maintain a minimum distance(50mm).

Rule Arguments

There are two rule arguments defined for this rule.

Filter: This argument specifies the types of the objects to be filtered such that rule process further on the filtered objects.

Minimum Distance: This argument specifies the minimum distance between any two holes to be maintained (default value- 50mm).