  1. Select the SIO pipe runs to convert.

  2. Select Tools > Utilities > Convert SIO to S3D Pipe Run to open the Convert SIO PipeRun to S3D Dialog.

  3. Select Generic Piping Components by Selected Spec to convert piping components without any mapping. Select a spec from the list. Alternatively, select Piping Parts by Mapping, and then navigate to the mapping file.

  4. Type a path and a log file name in the Log File box.

  5. Click Convert to start the command. The progress displays in the status bar. The software creates the Smart 3D pipe runs under the corresponding SIO pipeline, and appends _S3D to the selected SIO pipe run name. The software maintains the connectivity between the converted Smart 3D pipe runs.

  6. Click OK to dismiss the Process Completed message box.