Synchronize the work area definition from SDx - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Integration - Project As-Built with HxGN SDx

Language
English
Product
Intergraph Smart 3D
Subproduct
Project As-Built with SDx
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Synchronizing the work area definition from the As-Built model in SDx provides a reference for the Smart 3D project assigned to the external EPC.

  • We recommend stopping the Share service on the As-Built (Handover) model before synchronizing the work area to the Change Management model. When data merged to SDx in a Change Management workflow is reworked in the As-Built (Handover) model when the Share Service is running, overlapping objects in the work area can occur and lead to downstream integrity issues.

  • Before synchronizing the work area definition, you must define SDx subscription settings. Otherwise, the software displays an error message.

  1. Open Project Management, and select the registered Change Management model in the Project Management tree.

  2. Click Integration > Synchronize Work Area from SDx Command to open the SDx Synchronization Status window.

  3. Review the progress for the synchronize from SDx process. The Sync from SDx progress bar displays 100% when the work area definition is synchronized (1), and Sync Status in the Synchronize from SDx panel displays Completed (2).

  4. Click Close when finished.

  • If an instance of work area definition synchronization is currently in progress, the software displays a message.

  • After you synchronize the work area definition, you can claim the objects to be modified.