Copy SIO Pipe Run to Smart 3D Command - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Integration - Project As-Built with HxGN SDx

Language
English
Product
Intergraph Smart 3D
Subproduct
Project As-Built with SDx
Search by Category
Administration & Configuration
Smart 3D Version
13

Copies the selected Smart Interop Object (SIO) pipe runs to native Smart 3D pipe runs. In the Piping task, right-click the selected SIO pipe runs, and then select Copy SIO PipeRun to Smart 3D from the shortcut menu to open the CopySIOPipeRunToS3D Dialog.

Validating copied Smart 3D pipe runs

The two methods that enable you to validate the SIO pipe runs you copied to native Smart 3D pipe runs are described below.

Visual inspection

Superimpose the copied Smart 3D native model on the SIO model, and then verify that the topology and the piping part locations are accurate.

Check the log file

Click View Log on the CopySIOPipeRunToS3D Dialog, or navigate to the log file and open it in a text editor. Check the process summary, the source Object IDs, and locations for failures, warnings, or errors. Take any necessary actions to correct problems.

CopySIOPipeRunToS3D Dialog

What do you want to do?