You can generate the diagnostic reports using the Diagnostic custom command (FoulCheckCommand,Ingr.SP3D.FoulCheck.Client.Commands.RunIFCDiagnostics) in Project Management. Make sure you select the corresponding Model node before running the custom command.

The report is generated in the default delivered reports folder, for example, C:\Users\(login)\Smart3D\ReportOutput.

The following scenarios describe the report behavior:

Scenario 1: If the IFC process is not configured, then the Standard Diagnostics report is not generated.

Scenario 2: If the IFC process is configured but the Diagnostics is not enabled, then the RunDiagnostics command generates the following information.

  • IFC Standard Diagnostics

  • Existing R3D Information (if R3D information does not exist, then the corresponding worksheet is not generated)

  • Actions for R3D File Status (if R3D file information does not exist, then Admin Actions sheet is not generated)

  • Bad and Delayed parts information (if bad or deleted information does not exist, then the corresponding worksheet is not generated)

Scenario 3: If the Diagnostics is configured, then IFC process generates the corresponding XML files.