The following isometric contains a single piece of pipe with two bends, but no information about bend radii or angles is displayed on the isometric.
Likewise, when you view the PCF file in the Extraction Data Dialog, no information about angles and bend radii is present for either BEND record.
-
Right-click an Isogen Isometric Drawing by Query component or package in the Management Console or Drawing Console, and then click Edit Options to open Isogen Configuration.
-
From the Home screen, navigate to Smart 3D.Content.Components.
-
Click the check boxes for Output Bend Angle and Output Bend Radius, and set Bend Radius Format to Radius Multiplier.
Selecting Output Bend Angle only controls the writing of angle to the PCF. An Isogen option controls whether the angle is displayed.
-
Navigate to Dimensions.Display Format.Angles, and set Style to All.
-
Click to update the isometric style file with the new isometric drawing option settings, and then exit Isogen Configuration.
-
Update the drawing and review the isometric output using the View Extraction Data Command. The bend radii and the bend angles now display on the isometric.