Open Isogen Configuration, and navigate to Smart 3D.Content.General.
-
Set Flow Arrow Placement (see File Type) to PipeRun.
-
Click to update the isometric style file with the new isometric drawing option settings, and then exit Isogen Configuration.
-
Update the drawing, and use the View Extraction Data command to view the isometric output. The flow arrows are shown once per run.
-
Re-open Isogen Configuration, and navigate to Smart 3D.Content.General.
-
Set Flow Arrow Placement (see File Type) to PipeFeature.
-
Click to update the isometric style file with the new isometric drawing option settings, and then exit Isogen Configuration.
-
Update the drawing and review the isometric output using the View Extraction Data Command. The flow arrows are now shown once per feature.