Mitre Weld Text Tolerance - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Isogen Isometric Drawings

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Help
Smart 3D Version
13.1
Isogen Version
13.0(2016)

Controls the suppression of mitre weld angle messages on the isometric drawing.

When Isogen encounters a mitre weld in a pipeline, the system outputs a message on the isometric drawing that indicates the angle together with a standard alternative text.

Set Mitre Weld Text Tolerance to 0 to report all mitre weld angular changes on the drawing. To suppress change message output, type an angular value in degrees. Isogen does not report angular changes on the isometric drawing that fall below this value. The maximum user-specified angular value must be less than 10°.

Defines:

Option Switch - 115, Pos 4-6
I-Configure - Drawing.Controls.MitreWeldAngle

This property is not available for Smart 3D cable tray isometric drawings or Smart 3D HVAC isometric drawings.