Specifies a branch bore limit to suppress dimensions.
Type a value in the range 0-999. The value that you enter must be in millimeters or 1/16 inches, depending on the bore units setting. Branches that have a bore less than or equal to the specified value are not dimensioned. In the example, the branch has a bore less than the Nominal Size setting. Consequently, it is not dimensioned.
Defines:
Option Switch - 81, Pos 4-6
I-Configure - Drawing.Dimensions.BranchBoreLimit
-
To dimension all branches, type 0.
-
Isogen does not suppress branch dimensions for any branch that contains pipe or pipe block.
-
Isogen treats fixed length pipe as a component. As such, branch dimensions are suppressed.
-
Nominal Size can work independently of or in conjunction with Component Count, depending upon your requirements.
-
This property is not available for Smart 3D cable tray and Smart 3D HVAC models.