Controls the generation of bottom-of-pipe (BOP) coordinates at changes in pipeline elevation. By default, this option is turned off.

To generate BOP coordinates, select the check box. In most instances, Isogen uses the port that is the most horizontal (or flat) as the basis for the BOP callout. However, the software treats branches (olets and tees) differently. For headers that are between 0 and 45 degrees from the horizontal plane, the BOP is the underside of header. The software determines this location using a line perpendicular to the header centerline drawn from the center of the branch feature to the outside of the header pipe (1).

For headers that are greater than 45 degrees from the horizontal plane, the BOP is the underside of the branch (2).

Defines:

Option Switch - N/A
I-Configure - S3D.Drawing.Content.CoordOutputBOP