Columns - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Isogen Isometric Drawings

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Help
Smart 3D Version
13.1
Isogen Version
13.0(2016)

Defines the columns of data that Isogen plots in the variable layout weld list.

Open the grid, and then define the attributes listed below as needed.

  • Attribute specifies the name of the attribute to include in the report. Select an attribute in the list.

  • Justification sets the alignment of text in the column. Select Left, Numeric, or Right.

  • Offset specifies the offset in millimeters from the Start X and Start Y settings. Type the appropriate value.

  • Maximum Chars sets the width of the column. Type a value of zero or greater.

  • Comment outputs a text comment for any definition contained in the previous columns. Isogen outputs any text that you enter as a comment (preceded by a !) to the relevant data or summary report file.

The software displays a count of the number of columns that are defined for the report. This is a system-generated value. The example below indicates that three columns are currently defined.

Defines:

Option Switch - N/A
I-Configure - WeldList.VariableLayout