Specifies gasket dimensions.

You can choose not to show gasket dimensions, to include the dimension with the component, or to treat the dimension separately. Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • None suppresses gasket dimensions. Gasket thicknesses are not included. The component dimension is indicated by the presence of two leader lines.

  • Included includes gasket dimensions with the component. Gasket thicknesses are included. The component dimension is indicated by the presence of only single leader lines. As the example shows, the length of the valve has increased by the thickness of the gaskets on either side (2 mm in this case).

  • Separate dimensions gaskets separately.

Defines:

Option Switch - 9, Pos 2
I-Configure - Drawing.Dimensions.Gaskets